www.joyetv.com

Loader Multi Way Valve for Liugong 850H 12C3016

60

Loader Multi Way Valve for Liugong 850H 12C3016

Loader Multi-Way Valve for Liugong 850H 12C3016/Liugong 850H Loader Multi-Way Valve/XGMA 958 Loader Multi-way Valve 12C3016/Hydraulic Valve - Multi-way Valve 12C3016 Loader Multi-Way Valve for Liugong 850H 12C3016,Hydraulic Valve - Multi-way Valve 12C3016 Reasons for the multi-way valve hairpin of loader: 1. Cleanliness is the most likely reason for the issuance of the loader multi-way valve, hydraulic control multi-way valve and pilot valve, accounting for 80% of the probability. Because the multi-way valve sold to go through more than two experiments, if the cylindricity problem should be found before leaving the factory. You carefully remove the two main stem and inspect the stem and hole cavity for scratches. If there are local scratches, it is possible that something dirty got stuck inside and pulled the stem as it moved. If the scratch is deep, the leakage will be large, and the bucket will feel slow and not so strong after repair. Remove all components, especially the safety…